

- #Hp smart array p410i controller flash to initiator target install
- #Hp smart array p410i controller flash to initiator target serial
- #Hp smart array p410i controller flash to initiator target driver
Iocxgbe12: INITIALIZING HP Dual Port CNA 10Gb BL8X0c i4 Embedded CNIC at hardware path 0/0/0/3/0/0/2 Iocxgbe1: INITIALIZING HP Dual Port CNA 10Gb BL8X0c i4 Embedded CNIC at hardware path 0/0/0/3/0/0/1 Iocxgbe0: INITIALIZING HP Dual Port CNA 10Gb BL8X0c i4 Embedded CNIC at hardware path 0/0/0/3/0/0/0

#Hp smart array p410i controller flash to initiator target serial
System Console is on the Built-In Serial Interface Please check zone configuration on your switch.Ġ/0/0/5/0/0/1: Fabric Name Server rejected GPN_FT query.ĬISS: RAID SA P410i controller on hardware path 1/0/0/2/0/0/0 is now online.īoot device's HP-UX HW path is: 0/0/0/2/0/0/0.0x0.0x4000000000000000 This may indicate that the HBA port is not part of a zone. NOTICE: cachefsc_install: cachefs File system was registered at index 13.ĬISS: RAID SA P410i controller on hardware path 0/0/0/2/0/0/0 is now online.Ġ/0/0/5/0/0/0: Fabric Name Server rejected GPN_FT query. NOTICE: nfs_client_pv4_install(): nfs4 File system was registered at index 11. NOTICE: nfs_client_pv3_install(): nfs3 File system was registered at index 10. Rpcmod_install(): kernel RPC STREAMS module "rpcmod" installation.(driver_install) Secgss_init(): kernel RPCSEC_GSS security initialization. Sec_init(): kernel RPC authentication/security initialization. Installing Socket Protocol families AF_INET and AF_INET6 Spinlock ALAT switching supported on this related patching completed Larger names can cause some applications which use those names to behave incorrectly or fail. It is strongly recommended that all related manpages and documentation be understood before setting larger names. Warning: Setting the expanded_node_host_names parameter to 1 will allow administrators to set node and host names larger than 8 and 64 characters/bytes, respectively. This may result in unusable memory in each process. Warning: The value of 32767 for tunable maxfiles_lim is not a multiple of the file descriptor chunk size (8). Use the EFI boot manager or the EFI 'conconfig' command to select this device

If you would like thisĭevice to be the one used by HP-UX as the console output device, reboot and Remains on the screen for more than a few minutes, then this is not theĭevice in use by HP-UX as the console output device. WARNING: Multiple console output devices are configured. Loading MFSFILES directory (bootfs) to MFS Loading System Directory (boot.sys) to MFS HP-UX Boot Loader for IPF - Revision 2.047 (C) Copyright 1999-2012 Hewlett-Packard Development Company, L.P. So it breaks something.PRESS B or b =Select Entry X/x=Exit this Menu | I have checked my router and it never even pulls an IP. When trying to use IG-88's extra.lzma, I will get the boot screen saying to go find the server but NOTHING ever shows up on network. If I'm understanding things correctly this is due to the hpsa.ko driver not being present in Xpenology.
#Hp smart array p410i controller flash to initiator target install
When I use the p420i controller in HBA mode, everything seems to be installing as expected however, the install will not see any HDDs on the array. makes a massive racket and wasteful power usage. However after some reading I have found that if ANYTHING is in a PCI-e slot on the server it will spin up two fans baseline to 35-45%. When I use my PCI-e LSI 9211-8i HBA card, I have no issues with the install or running DSM. Using "hpssacli controller slot=0 modify Hbamode=on forced" and then confirmed that the controller was in HBA mode, also show in POST. However following a few guides online I was able to use the HP SPP disk to boot into the raid controller. I'll solve to switch to HBA mode - already checked That statement was for the internal p420 RAID controller on the D元80p Gen8.

#Hp smart array p410i controller flash to initiator target driver
My friend already created the necessary USB stick for me, how can I add this extra driver package to it? I'm an absolute beginner so I'm not fully understand what should I do. You can use this extra.lzma for 3615/3617 for testing I guess you used 3617? (918+ needs 4th gen intel and that model seems to have only ivy bridge) Most people go with a cheap 9211-8i (reflashed oem clone) with IT firmware, it has two sas connectors so you should be able to connect the backplane of the server I can't remember that we had someone doing it and using the hpsa.ko driver successfully For one you would need additional driver as extra.lzma (you can open this with 7zip, the file that needs to be there is hpsa.ko)Īlso its best to set the p420 in non-raid or hba modeĪfair that can be done in the ssa utility, reset raid configuration and then choose hba mode, you can google it or look on youtube, there should be detailed information
